Current research projects

Image Helium extraction from natural gas
Image Low Temperature Tribology
Image Ionocaloric cooling
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image Breakthrough Sensor for Adsorption Filters (BelA)
Image Corrosion inhibitor for ammonia absorption systems
Image Cool Up
Image Testing of mobile leak detectors according to DIN EN 14624
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Performance tests of condensing units
Image Software for test rigs
Image State of system and failure analyses
Image Cryogenic liquid piston pumps for cold liquefied gases like LIN, LOX, LHe, LH2, LNG, LAr
Image Combined building and system simulation
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Hybrid- Fluid for CO2-Sublimation Cycle

You are here:  Home /  Testing Equipment


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects - Testing Equipment

Image

Ice Slurry Generation

Using Direct Evaporation

Image

Pulse-Tube-Refrigerator with sealed compressor

for mobil use in the hydrogen technology

Image

3D - Air flow sensor

Anemometer for determination of 3d-air flow