Current research projects

Image Breakthrough Sensor for Adsorption Filters (BelA)
Image Combined building and system simulation
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image Tribological investigations of oil-refrigerant-material-systems
Image Micro heat exchangers in refrigeration
Image Multifunctional electronic modules for cryogenic applications
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image ZeroHeatPump
Image Test method for high - temperature heat pump - oils
Image Reducing the filling quantity
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Corrosion inhibitor for ammonia absorption systems
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image 3D - Air flow sensor

You are here:   /  Home


Thermostatic Expansion Valves

Industry

Dr.-Ing. Matthias Böhm

+49-351-4081-5211

Does the TXV function correctly?

We support the industry in the development of energy-efficient vapor-compression refrigeration system and compression heat pumps.

The ILK Dresden offers the following services for you:

The ILK Dresden have been active in the field of performance testing of refrigeration compressors and condensing units for over 20 years.

Our offer includes also the investigation of thermostatic expansion valves (TEV) with external temperature sensors.

The tests of the TEV are carried out on a suitable refrigeration cycles (fig. 2), taking into account the following standards

  • AHRI 750 (2007),
  • ANSI/ ASHRAE 17 (2008, fig. 1) and
  • ASERCOM-Statement (9_GER_Dimensionierung_von_TXV_2011)

Current calibrations of the measuring systems are a matter of course.

The test can be carried out with the refrigerants R134a, R404A, R407A, R407C, R407F, R448A, R513A, R452A up to a mass flow of 400 kg/h (~20 kW for R134a).

Additional offerings

The following influences on the valve behaviour can be investigated

  • run-in period
  • hysteresis
  • transient tests / time constant
  • pressure losses
  • sub cooling
  • ambient temperature
  • critical pressure ratio

Your Request

Further Projects

Image

Testzentrum PLWP at ILK Dresden

Test Fluid-Energy Machines and Components

Image

Performance tests of refrigerant compressors

Does your compressor perform well?

Image

Swirl-free on the move...

...with a contra-rotating fan

Image

Measurement of insulated packaging

How efficient is my cool box?

Image

Hybrid- Fluid for CO2-Sublimation Cycle

Cryogenic cooling by CO2 sublimation