Current research projects

Image Verification of storage suitability of cryo tubes
Image Hydrogen and methane testing field at the ILK
Image Panel with indirect evaporative cooling via membrane
Image Tensile and compression testing
Image Ionocaloric cooling
Image High Capacity Pulse Tube Cooler
Image Preformance measurements of heat exchangers
Image Air-water heat pumps
Image Computational fluid dynamics CFD
Image Helium extraction from natural gas
Image Test rigs for refrigeration and heat pump technology
Image Non- invasive flow measurements
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Testing of mobile leak detectors according to DIN EN 14624
Image Low Temperature Measuring Service

You are here:   /  Home


Thermostatic Expansion Valves

Industry

Dr.-Ing. Matthias Böhm

+49-351-4081-5211

Does the TXV function correctly?

We support the industry in the development of energy-efficient vapor-compression refrigeration system and compression heat pumps.

The ILK Dresden offers the following services for you:

The ILK Dresden have been active in the field of performance testing of refrigeration compressors and condensing units for over 20 years.

Our offer includes also the investigation of thermostatic expansion valves (TEV) with external temperature sensors.

The tests of the TEV are carried out on a suitable refrigeration cycles (fig. 2), taking into account the following standards

  • AHRI 750 (2007),
  • ANSI/ ASHRAE 17 (2008, fig. 1) and
  • ASERCOM-Statement (9_GER_Dimensionierung_von_TXV_2011)

Current calibrations of the measuring systems are a matter of course.

The test can be carried out with the refrigerants R134a, R404A, R407A, R407C, R407F, R448A, R513A, R452A up to a mass flow of 400 kg/h (~20 kW for R134a).

Additional offerings

The following influences on the valve behaviour can be investigated

  • run-in period
  • hysteresis
  • transient tests / time constant
  • pressure losses
  • sub cooling
  • ambient temperature
  • critical pressure ratio

Your Request

Further Projects

Image

Heat2Power

Refining of fuel cell waste heat

Image

Reducing the filling quantity

How much refrigerant must be filled?

Image

Performance tests of condensing units

Does your condensing unit perform well?

Image

State of system and failure analyses

Cause of the failure unknown?