Current research projects

Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Reduction of primary noise sources of fans
Image Cold meter
Image Investigation of material-dependent parameters
Image Low Temperature Tribology
Image Practical training, diploma, master, bachelor
Image Software for technical building equipment
Image Performance tests of refrigerant compressors
Image Thermostatic Expansion Valves
Image Test method for high - temperature heat pump - oils
Image Breakthrough Sensor for Adsorption Filters (BelA)
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Verification of storage suitability of cryo tubes
Image Behavior of multiphase cryogenic fluids
Image Measurement of insulated packaging
Image Development of test methods and test rigs for stationary integrated refrigeration units

You are here:  Home /  Research and Development


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects - Research and Development

Image

Micro fluidic expansion valve

for increasing of the efficiency of small and compact cooling units

Image

Hydrogen and methane testing field at the ILK

Simultaneously pressures up to 1,000 bar, temperatures down to –253°C

Image

Low noise and non metallic liquid-helium cryostat

Low-noise Magnetic Field Cryostat for SQUID-Applications

Image

Cryostats, Non-Metallic and Metallic

position indenpendent, highest endurance, tiltable for liquid helium and liquid nitrogen