Current research projects

Image Ionocaloric cooling
Image Heat2Power
Image Low noise and non metallic liquid-helium cryostat
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Reducing the filling quantity
Image Service offer for Leak Detection and Tightness Test
Image Intelligent innovative power supply for superconducting coils
Image Pulse-Tube-Refrigerator with sealed compressor
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Corrosion inhibitor for ammonia absorption systems
Image Filter Tests
Image Production of novel barrier layers on polymer materials to reduce hydrogen permeation
Image Investigation of material-dependent parameters
Image Laseroptical measurement
Image Non- invasive flow measurements
Image Electrical components in refrigeration circuits

You are here:  Home /  Research and Development


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects - Research and Development

Image

Micro fluidic expansion valve

for increasing of the efficiency of small and compact cooling units

Image

Hydrogen and methane testing field at the ILK

Simultaneously pressures up to 1,000 bar, temperatures down to –253°C

Image

Low noise and non metallic liquid-helium cryostat

Low-noise Magnetic Field Cryostat for SQUID-Applications

Image

Cryostats, Non-Metallic and Metallic

position indenpendent, highest endurance, tiltable for liquid helium and liquid nitrogen