Current research projects

Image Measurements on ceiling mounted cooling systems
Image Practical training, diploma, master, bachelor
Image Helium extraction from natural gas
Image Investigation of material-dependent parameters
Image Air-water heat pumps
Image Energy efficiency consulting - cogeneration systems
Image Refrigerants, lubricants and mixtures
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Swirl-free on the move...
Image Optimizing HVAC operation with machine learning
Image Electrical components in refrigeration circuits
Image Calibration of Low Temperature Sensors
Image Software modules
Image Humidifier System for High-Purity Gases
Image Investigation of materials
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K

You are here:  Home /  Measurements and Tests


Thermostatic Expansion Valves

Industry

Dr.-Ing. Matthias Böhm

+49-351-4081-5211

Does the TXV function correctly?

We support the industry in the development of energy-efficient vapor-compression refrigeration system and compression heat pumps.

The ILK Dresden offers the following services for you:

The ILK Dresden have been active in the field of performance testing of refrigeration compressors and condensing units for over 20 years.

Our offer includes also the investigation of thermostatic expansion valves (TEV) with external temperature sensors.

The tests of the TEV are carried out on a suitable refrigeration cycles (fig. 2), taking into account the following standards

  • AHRI 750 (2007),
  • ANSI/ ASHRAE 17 (2008, fig. 1) and
  • ASERCOM-Statement (9_GER_Dimensionierung_von_TXV_2011)

Current calibrations of the measuring systems are a matter of course.

The test can be carried out with the refrigerants R134a, R404A, R407A, R407C, R407F, R448A, R513A, R452A up to a mass flow of 400 kg/h (~20 kW for R134a).

Additional offerings

The following influences on the valve behaviour can be investigated

  • run-in period
  • hysteresis
  • transient tests / time constant
  • pressure losses
  • sub cooling
  • ambient temperature
  • critical pressure ratio

Your Request

Further Projects - Measurements and Tests

Image

Solar Cooling

Solar Cooling with Photovoltaic

Image

Hydrogen and methane testing field at the ILK

Simultaneously pressures up to 1,000 bar, temperatures down to –253°C

Image

Calibration of Low Temperature Sensors

According to the comparative measurement method

Image

Low Temperature Measuring Service

Measurement of Thermal Properties at Low Temperatures

Image

Test procedures for electrical components

Insulating properties of hermetic compressors